- Date
- 11/17/2017
- W/O
- 0674089
- Weather
- Light Rain
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00471
- PipeID
- P06954
- Time
- 3:04 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- H0674
- Sewer Name
- 05 LOMITA TRUNK
- City
- LOMITA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 32
- Purpose
- Routine Assessment
- Project
- 20171117MDM_LOMITA_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 05 1726
- Downstream MH
- 05 1727
- Dir. of Survey
- Upstream
- Length Surveyed
- 328.5 ft.
- Total Length
- 328.5 ft.
- Structural Index
- 3
- Structural Quick
- 3722
- Structural Rating
- 25
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 29
Pipe schematic from manhole 05 1726 to 05 1727 Observation photos (5)

8.3 ft. - General Observation - 21" VCP

60.1 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Start - H

116.9 ft. - Fracture Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES, Start - H

136.9 ft. - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES, Start - H

252.1 ft. - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT