Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 16, 2017, 04:51 PM
  • H 0409_H 0408_11162017_102248.mp4

Date
11/16/2017
W/O
0673491
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00177
PipeID
P10843
Time
8:51 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7559
Sewer Name
H JOINT OUTFALL H - UNIT 5A
City
WHITTIER
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
33
Purpose
Routine Assessment
Project
20171116SHO_JOINT_OUTFALL_H_UNIT_5A
Material
Reinforced Concrete Pipe
Shape
Circular
Height
63 in.
Upstream MH
H 0409
Downstream MH
H 0408
Dir. of Survey
Downstream
Length Surveyed
517 ft.
Total Length
517 ft.
Structural Index
3
Structural Quick
5131
Structural Rating
10
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole H 0409 to H 0408
MH: H 0409MH: H 0408downstream0 ft. AMH - Upstream Manhole, Survey Begins - 10200 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start17.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start516.4 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES516.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish516.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish517 ft. AMH - Downstream Manhole, Survey Ends - 1045

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    17.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

    516.4 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
516.4SRV
17.9SSS
516.4SAP
0AMH1020
0MWM
516.4SSS
8SAP
0MWL
517AMH1045

Properties (6)

custom_field_three
MOSTLY PROJECTING AGG. & SPALLING
custom_field_two
3
customer
LACSD
datetime
2017-11-16T08:51:05-08:00
documentation
OBREGON, IGNACIO, BRAR, VENDRYES, PARAISO
is_lateral_inspection
false