Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 22, 2015, 09:47 AM
  • 02 1097_02 1096_20151022_020255.mp4

Date
10/22/2015
W/O
521067
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00300
PipeID
P04597
Time
2:47 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2811
Sewer Name
02 RANDOLPH STREET TRUNK
City
COMMERCE
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
20
Purpose
Routine Assessment
Project
WO_521067_TV02229_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
02 1097
Downstream MH
02 1096
Dir. of Survey
Downstream
Length Surveyed
345.7 ft.
Total Length
345.7 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 02 1097 to 02 1096
MH: 02 1097MH: 02 1096downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 10970 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - ROACHES IN MH0 ft. MWM - Water Mark, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start30.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start144.9 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"344.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish344.6 ft. MGO - General Observation - ROACHES IN MH344.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish345.7 ft. AMH - Downstream Manhole, Survey Ends - 02 1096

Observations (11)

DistanceCodeObservation
344.6CM
0AMH02 1097
30.9CM
344.6MGOROACHES IN MH
144.9TBA
0MWL
344.6DAGS
0MGOROACHES IN MH
0MWM
2DAGS
345.7AMH02 1096

Properties (6)

additional_info
SC203942
custom_field_two
4
customer
LACSD
datetime
2015-10-22T02:47:59-07:00
documentation
PRO PIPE
is_lateral_inspection
false