Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 22, 2015, 08:48 AM
  • 02 1099_02 1098A_20151022_005459.mp4

Date
10/22/2015
W/O
521067
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00300
PipeID
P03673
Time
1:48 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2811
Sewer Name
02 RANDOLPH STREET TRUNK
City
COMMERCE
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
20
Purpose
Routine Assessment
Project
WO_521067_TV02229_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
02 1099
Downstream MH
02 1098A
Dir. of Survey
Downstream
Length Surveyed
111.5 ft.
Total Length
111.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 1099 to 02 1098A
MH: 02 1099MH: 02 1098Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 10990 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0.1 ft. MGO - General Observation - ROACHES IN MH2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start90.9 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"109.2 ft. MGO - General Observation - ROACHES IN MH109.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish111.5 ft. AMH - Downstream Manhole, Survey Ends - 02 1098A111.5 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK

Observations (10)

DistanceCodeObservation
0AMH02 1099
109.2MGOROACHES IN MH
90.9TBA
0MWM
109.2DAGS
111.5AMH02 1098A
2DAGS
0.1MGOROACHES IN MH
111.5MGOACTIVE CONNECTION AT MH 3 O'CLOCK
0MWL

Properties (6)

additional_info
SC203942
custom_field_two
4
customer
LACSD
datetime
2015-10-22T01:48:04-07:00
documentation
PRO PIPE
is_lateral_inspection
false