Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 26, 2018, 11:31 AM
  • 04 0035_04 0034_26032018_044143.mp4

Date
03/26/2018
W/O
690446
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00416
PipeID
P11763
Time
4:31 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5498
Sewer Name
04 SHERMAN RELIEF TRUNK
City
WEST HOLLYWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 04
Page No.
01
Purpose
Routine Assessment
Project
WO_690446_TV04026_MAR2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
04 0035
Downstream MH
04 0034
Dir. of Survey
Downstream
Length Surveyed
406.4 ft.
Total Length
406.4 ft.
Structural Index
3
Structural Quick
3O00
Structural Rating
243
O&M Index
3
O&M Quick
3M00
O&M Rating
210
Overall Index
3
Overall Quick
Overall Rating
453
Pipe schematic from manhole 04 0035 to 04 0034
MH: 04 0035MH: 04 0034downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 04 00352 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start47.9 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS396 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish - B405 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish406.4 ft. MGO - General Observation - COCKROACHES IN MANHOLE406.4 ft. AMH - Downstream Manhole, Survey Ends - 04 0034

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
2SAV
0MWM
396DSZB
0MWL
405SAV
0AMH04 0035
406.4MGOCOCKROACHES IN MANHOLE
406.4AMH04 0034
47.9DSZDEBRIS

Properties (6)

additional_info
SC358506, PROJECT BAR SHOULD SAY NRCP INSTEAD OF VCP
custom_field_two
3
customer
LACSD
datetime
2018-03-26T04:31:55-07:00
documentation
PRO PIPE
is_lateral_inspection
false