Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 9, 2016, 06:41 PM
  • 22 0670A_22 0670_20160509_125246.mp4

Date
05/09/2016
W/O
568953
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00827
PipeID
P17020
Time
11:41 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3247
Sewer Name
22 SUNFLOWER TRUNK
City
SAN DIMAS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
22
Purpose
Routine Assessment
Project
WO_568953_TV22063_MAY2016
Sewer Type
GRAVITY
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
22 0670
Downstream MH
22 0670A
Dir. of Survey
Upstream
Length Surveyed
202.5 ft.
Total Length
202.5 ft.
Structural Index
3
Structural Quick
3G00
Structural Rating
120
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
124
Pipe schematic from manhole 22 0670 to 22 0670A
MH: 22 0670MH: 22 0670Aupstream0 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 22 0670A0.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish0.4 ft. MGO - General Observation - Magnesium hydroxide coating finish2.5 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish29.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"34.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"102.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"106.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"176.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"181 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"199.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start200.5 ft. MGO - General Observation - Magnesium hydroxide coating start200.5 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start202.5 ft. MWM - Water Mark, 15 %of cross sectional area202.5 ft. MWL - Water Level, 10 %of cross sectional area202.5 ft. AMH - Downstream Manhole, Survey Begins - 22 0670

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
95.8TFC
202.5MGOCONNECTION AT THE MH 9 O'CLOCK
21.5TFC
2MGOMagnesium hydroxide coating start
0MWM
0MWL
168.2TFC
2SAV
26.2TFC
202.1DAGS
202.5AMH22 0670A
202.1MGOMagnesium hydroxide coating finish
100.1TFC
200SAV
0AMH22 0670
173TFC
2.7DAGS

Properties (6)

additional_info
SC305346
custom_field_two
3
customer
LACSD
datetime
2016-05-09T11:41:35-07:00
documentation
PRO PIPE
is_lateral_inspection
false