Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 9, 2016, 06:57 PM
  • 22 0671_22 0670A_20160509_130150.mp4

Date
05/09/2016
W/O
568953
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00827
PipeID
P17021
Time
11:57 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3247
Sewer Name
22 SUNFLOWER TRUNK
City
SAN DIMAS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
22
Purpose
Routine Assessment
Project
WO_568953_TV22063_MAY2016
Sewer Type
GRAVITY
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
22 0670A
Downstream MH
22 0671
Dir. of Survey
Upstream
Length Surveyed
42.5 ft.
Total Length
42.5 ft.
Structural Index
3
Structural Quick
3800
Structural Rating
24
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
28
Pipe schematic from manhole 22 0670A to 22 0671
MH: 22 0670AMH: 22 0671upstream0 ft. AMH - Upstream Manhole, Survey Ends - 22 06711.6 ft. MGO - General Observation - Magnesium hydroxide coating finish2.5 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish40.5 ft. MGO - General Observation - Magnesium hydroxide coating start40.5 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start42.5 ft. MWM - Water Mark, 50 %of cross sectional area42.5 ft. AMH - Downstream Manhole, Survey Begins - 22 0670A42.5 ft. MWL - Water Level, 30 %of cross sectional area

Observations (8)

DistanceCodeObservation
40.9MGOMagnesium hydroxide coating finish
2MGOMagnesium hydroxide coating start
0MWM
2SAV
0AMH22 0670A
42.5AMH22 0671
0MWL
40SAV

Properties (6)

additional_info
SC305346
custom_field_two
3
customer
LACSD
datetime
2016-05-09T11:57:16-07:00
documentation
PRO PIPE
is_lateral_inspection
false