Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 9, 2016, 08:23 AM
  • 22 0677_22 0676_20160509_025104.mp4

Date
05/09/2016
W/O
568953
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00827
PipeID
P17027
Time
1:23 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3246
Sewer Name
22 SUNFLOWER TRUNK
City
SAN DIMAS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
23
Purpose
Routine Assessment
Project
WO_568953_TV22063_MAY2016
Sewer Type
GRAVITY
Material
NRCP
Shape
Circular
Height
12 in.
Upstream MH
22 0677
Downstream MH
22 0676
Dir. of Survey
Downstream
Length Surveyed
418.9 ft.
Total Length
418.9 ft.
Structural Index
3
Structural Quick
3P00
Structural Rating
249
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
251
Pipe schematic from manhole 22 0677 to 22 0676
MH: 22 0677MH: 22 0676downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 06770 ft. MWL - Water Level, 5 %of cross sectional area0 ft. VC - Vermin Cockroach2 ft. MGO - General Observation - Magnesium hydroxide coating start2 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start25.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"95.4 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"100.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"171 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"174.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"245 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"249.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"299.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"304.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"359.2 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"364.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"415.7 ft. MGO - General Observation - Magnesium hydroxide coating finish416 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish418.9 ft. AMH - Downstream Manhole, Survey Ends - 22 0676418.9 ft. VC - Vermin Cockroach418.9 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK

Observation photos (2)

  • General Observation - Magnesium hydroxide coating finish

    415.7 ft. - General Observation - Magnesium hydroxide coating finish

  • Vermin Cockroach

    418.9 ft. - Vermin Cockroach

Observations (21)

DistanceCodeObservation
359.2TFC
0AMH22 0677
299.7TFC
415.7MGOMagnesium hydroxide coating finish
2MGOMagnesium hydroxide coating start
304.5TFA
416SAV
418.9AMH22 0676
95.4TFC
0MWL
25.7TFC
418.9VC
245TFC
249.7TFA
100.4TFC
2SAV
364.1TFC
171TFC
174.8TFA
418.9MGOCONNECTION AT THE MH 9 O'CLOCK
0VC

Properties (6)

additional_info
SC305344
custom_field_two
3
customer
LACSD
datetime
2016-05-09T01:23:16-07:00
documentation
PRO PIPE
is_lateral_inspection
false