Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 17, 2016, 01:52 PM
  • 22 0614_22 0613_20160517_003527.mp4

Date
05/17/2016
W/O
568953
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00827
PipeID
P16961
Time
6:52 AM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3457
Sewer Name
22 SUNFLOWER TRUNK
City
COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
27
Purpose
Routine Assessment
Project
WO_568953_TV22063_MAY2016
Sewer Type
GRAVITY
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
22 0614
Downstream MH
22 0613
Dir. of Survey
Downstream
Length Surveyed
433.2 ft.
Total Length
433.2 ft.
Structural Index
3
Structural Quick
3P00
Structural Rating
258
O&M Index
2
O&M Quick
2P11
O&M Rating
173
Overall Index
2
Overall Quick
Overall Rating
431
Pipe schematic from manhole 22 0614 to 22 0613
MH: 22 0614MH: 22 0613downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 06140 ft. VC - Vermin Cockroach, within 8 inches of joint: NO0 ft. MWL - Water Level, 30 %of cross sectional area1.9 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start1.9 ft. MGO - General Observation - MAG COATING1.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start42 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"66.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"86.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"136.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"208.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"212.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"260.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"264.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"308.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"312.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"360.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"364.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"430 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish430.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish433.2 ft. AMH - Downstream Manhole, Survey Ends - 22 0613433.2 ft. MGO - General Observation - CONNECTION AT MH ACTIVE 9 OCLOCK

Observation photos (4)

  • Vermin Cockroach, within 8 inches of joint: NO

    0 ft. - Vermin Cockroach, within 8 inches of joint: NO

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    1.9 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COATING

    1.9 ft. - General Observation - MAG COATING

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    1.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (23)

DistanceCodeObservation
430SAV
264.6TFA
212.5TFC
430.4DAGS
0MWM
136.9TFC
0AMH22 0614
360.5TFC
433.2AMH22 0613
0VC
208.7TFC
0MWL
433.2MGOCONNECTION AT MH ACTIVE 9 OCLOCK
1.9SAV
308.4TFC
66.1TFC
260.5TFC
364.3TFC
86.3TF
1.9MGOMAG COATING
42TF
312.1TFC
1.9DAGS

Properties (6)

additional_info
SC305479
custom_field_two
3
customer
LACSD
datetime
2016-05-17T06:52:57-07:00
documentation
PROPIPE
is_lateral_inspection
false