Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 6, 2016, 08:19 AM
  • 22 0685_22 0684A_20160506_023250.mp4

Date
05/06/2016
W/O
568953
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00827
PipeID
P17037
Time
1:19 AM
Certificate
U- 109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K 3203
Sewer Name
22 SUNFLOWER TRUNK
City
SAN DIMAS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
15
Purpose
Routine Assessment
Project
WO_568953_TV22063_MAY2016
Sewer Type
GRAVITY
Material
NRCP
Shape
Circular
Height
12 in.
Upstream MH
22 0685
Downstream MH
22 0684A
Dir. of Survey
Downstream
Length Surveyed
248.9 ft.
Total Length
248.9 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
132
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
134
Pipe schematic from manhole 22 0685 to 22 0684A
MH: 22 0685MH: 22 0684Adownstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK0 ft. VC - Vermin Cockroach0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 22 06852 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. MGO - General Observation - CONNECTION AT THE MH 20% O'CLOCK59.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"65.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"119.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"124.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"184.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"189.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"245.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish245.3 ft. MGO - General Observation - Magnesium hydroxide coating 20% finish248.9 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK248.9 ft. VC - Vermin Cockroach248.9 ft. AMH - Downstream Manhole, Survey Ends - 22 0684A

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (19)

DistanceCodeObservation
2SAV
2MGOCONNECTION AT THE MH 20% O'CLOCK
0MWL
0MGOCONNECTION AT THE MH 9 O'CLOCK
119.4TFC
189.3TFC
248.9MGOCONNECTION AT THE MH 9 O'CLOCK
0VC
245.3SAV
0MWM
0MGOCONNECTION AT THE MH 3 O'CLOCK
248.9VC
0AMH22 0685
248.9AMH22 0684A
245.3MGOMagnesium hydroxide coating 20% finish
59.7TFC
65.5TFC
184.2TF
124.3TFC

Properties (6)

additional_info
SC300651
custom_field_two
3
customer
LACSD
datetime
2016-05-06T01:19:09-07:00
documentation
PRO PIPE
is_lateral_inspection
false