Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 19, 2017, 09:53 AM
  • 18 0731_18 0730 _20170519_025656.mp4

Date
05/19/2017
W/O
635639
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00706
PipeID
P14584
Time
2:53 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4500
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
26
Purpose
Routine Assessment
Project
WO_635639_TV18103_MAY2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
18 0731
Downstream MH
18 0730
Dir. of Survey
Downstream
Length Surveyed
66 ft.
Total Length
66 ft.
Structural Index
4
Structural Quick
5A3A
Structural Rating
96
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
96
Pipe schematic from manhole 18 0731 to 18 0730
MH: 18 0731MH: 18 0730downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 07310 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area6.1 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start65.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish66 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish66 ft. AMH - Downstream Manhole, Survey Ends - 18 0730

Observation photos (2)

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.1 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
0AMH18 0731
0MGOCONNECTION AT MH 3 O'CLOCK
0MWM
66SRV
6.1SRV
0MWL
65.3SAP
66AMH18 0730
6.1SAP

Properties (6)

additional_info
SC345310
custom_field_two
2
customer
LACSD
datetime
2017-05-19T02:53:15-07:00
documentation
PROPIPE
is_lateral_inspection
false