Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 30, 2016, 06:04 AM
  • F 0037_F 0036 _063016_003041.mp4

Date
06/29/2016
W/O
579949
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00034
PipeID
P10122
Time
11:04 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3556
Sewer Name
F JOINT OUTFALL F - UNIT 2
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
02
Purpose
Routine assessment
Project
WO_79949_TV03095_JULY2016
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
63 in.
Width
63 in.
Upstream MH
F 0037
Downstream MH
F 0036
Dir. of Survey
Downstream
Length Surveyed
605.3 ft.
Total Length
605.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole F 0037 to F 0036
MH: F 0037MH: F 0036downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - F 0037183.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"215.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"430.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"454.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"563.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"605.3 ft. AMH - Downstream Manhole, Survey Ends - F 0036

Observations (9)

DistanceCodeObservation
563.4TF
430.7TF
183.9TFA
0MWM
454.2TF
605.3AMHF 0036
215.4TFA
0MWL
0AMHF 0037

Properties (8)

additional_info
SC305861
custom_field_two
4
customer
LACSD
datetime
2016-06-29T23:04:11-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
FR POLY LINE
year_laid
35788