Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 7, 2016, 07:49 AM
  • 02 0359_02 0358_070716_005023.mp4

Date
07/07/2016
W/O
574757
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00259
PipeID
P02673
Time
12:49 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3560
Sewer Name
02 EAST COMPTON BOULEVARD RELIEF TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
33
Purpose
Routine Assessment
Project
WO_574757_TV02059_JUNE2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0358
Downstream MH
02 0359
Dir. of Survey
Upstream
Length Surveyed
123.3 ft.
Total Length
123.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 02 0358 to 02 0359
MH: 02 0358MH: 02 0359upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 0359123.3 ft. AMH - Downstream Manhole, Survey Begins - 02 0358123.3 ft. MWL - Water Level, 5 %of cross sectional area123.3 ft. MWM - Water Mark, 5 %of cross sectional area

Observations (4)

DistanceCodeObservation
0AMH02 0358
0MWL
0MWM
123.3AMH02 0359

Properties (6)

additional_info
SC305866
custom_field_two
4
customer
LACSD
datetime
2016-07-07T00:49:17-07:00
documentation
PROPIPE
is_lateral_inspection
false