Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 8, 2016, 06:24 AM
  • 02 0344B_02 0344A _070716_232442.mp4

Date
07/07/2016
W/O
574757
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00259
PipeID
P02658
Time
11:24 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3562
Sewer Name
02 EAST COMPTON BOULEVARD RELIEF TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
33
Purpose
Routine Assessment
Project
WO_574757_TV02059_JUNE2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0344B
Downstream MH
02 0344A
Dir. of Survey
Downstream
Length Surveyed
262.6 ft.
Total Length
262.6 ft.
Structural Index
3
Structural Quick
3300
Structural Rating
9
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 02 0344B to 02 0344A
MH: 02 0344BMH: 02 0344Adownstream0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - 02 0344B11.5 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES15 ft. CM - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES18.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start259.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish262.6 ft. AMH - Downstream Manhole, Survey Ends - 02 0344A262.6 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK

Observation photos (3)

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    11.5 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    15 ft. - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    18.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
262.6AMH02 0344A
0MWM
11.5CM
259.9CM
262.6MGOCONNECTION AT THE MH 9 OC'LOCK
0MWL
15CM
0MGOCONNECTION AT THE MH 3 OC'LOCK
0AMH02 0344B
18.4CM

Properties (6)

additional_info
SC305868
custom_field_two
3
customer
LACSD
datetime
2016-07-07T23:24:26-07:00
documentation
PROPIPE
is_lateral_inspection
false