Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 23, 2016, 07:32 AM
  • 02 0589_02 0588 _09232016_003244.mp4

Date
09/23/2016
W/O
592159
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00258
PipeID
P03133
Time
12:32 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3716
Sewer Name
02 EAST COMPTON BOULEVARD EXTENSION TRUNK
City
BELLFLOWER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
36
Purpose
Routine Assessment
Project
WO_592159_TV02289_SEP2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0588
Downstream MH
02 0589
Dir. of Survey
Upstream
Length Surveyed
280.9 ft.
Total Length
280.9 ft.
Structural Index
4
Structural Quick
4800
Structural Rating
32
O&M Index
2
O&M Quick
2J00
O&M Rating
110
Overall Index
2
Overall Quick
Overall Rating
142
Pipe schematic from manhole 02 0588 to 02 0589
MH: 02 0588MH: 02 0589upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 05890.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish0.9 ft. MWLS - Water Level, Sag in pipe, 70 %of cross sectional area, Finish42.9 ft. MWLS - Water Level, Sag in pipe, 70 %of cross sectional area, Start106.2 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 3"130.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 4"240.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"273.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start280.9 ft. AMH - Downstream Manhole, Survey Begins - 02 0588280.9 ft. MWM - Water Mark, 25 %of cross sectional area280.9 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    7.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
40.2TF
150.6TFA
280.9AMH02 0589
7.3DAGS
0AMH02 0588
174.7TB
0MWM
0MWL
280MWLS
238MWLS
280.8DAGS

Properties (6)

additional_info
SC303702
custom_field_two
4
customer
LACSD
datetime
2016-09-23T00:32:00-07:00
documentation
PRO-PIPE
is_lateral_inspection
false