Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 12, 2016, 09:11 PM
  • 02 0809_02 0808_20160804_100353.mp4

Date
07/12/2016
W/O
574316
Weather
Dry
Operator/Surveyor
N. ZAHREDDINE
Sewer ID
Z00294
PipeID
P03375
Time
2:11 PM
Certificate
N/A
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3204
Sewer Name
02 OLD RIVER SCHOOL ROAD TRUNK, SECTS 1&2
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
24
Purpose
Routine Assessment
Project
WO_574316_TV02111_JUNE2016
Sewer Type
ZZ
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
02 0809
Downstream MH
02 0808
Dir. of Survey
Downstream
Length Surveyed
312.1 ft.
Total Length
312.1 ft.
Structural Index
4
Structural Quick
4A32
Structural Rating
50
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
50
Pipe schematic from manhole 02 0809 to 02 0808
MH: 02 0809MH: 02 0808downstream0 ft. MGO - General Observation - VERMIN COCKROACH0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 08090 ft. MWM - Water Mark, 30 %of cross sectional area12 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4", 4"13 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"29.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES53.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"55.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES57 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"70.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES114 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"114.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 4"152 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 4"154.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"160.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES200.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"203 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"212 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES238.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES253.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"257 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"265 ft. FM - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES276.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES282.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start295.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"299 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"309.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish312.1 ft. AMH - Downstream Manhole, Survey Ends - 02 0808

Observation photos (8)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    29.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    55.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    70.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    160.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    212 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    238.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    265 ft. - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    282.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (29)

DistanceCodeObservation
152TFC
0MGOVERMIN COCKROACH
200.1TFC
312.1AMH02 0808
160.1FM
0MWL
29.1FM
238.1CM
295.1TFC
257TFC
276.1FM
12TFC
55.1FM
253.1TFC
0AMH02 0809
282.1FM
309.1FM
13TFC
203TFC
212FL
57TFC
70.1FM
0MWM
265FM
154.1TFC
114TFC
114.1TFC
299TF
53.1TF

Properties (6)

additional_info
SC300662
custom_field_two
2
customer
LACSD
datetime
2016-07-12T14:11:00-07:00
documentation
PROPIPE
is_lateral_inspection
false