Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 13, 2018, 08:15 AM
  • 08 0033_08 0032 _13042018_012946.mp4

Date
04/13/2018
W/O
694025
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00016
PipeID
P00035
Time
1:15 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5529
Sewer Name
08 MAIN STREET TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
07
Purpose
Routine Assessment
Project
WO_694025_TV08116_APR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
08 0033
Downstream MH
08 0032
Dir. of Survey
Downstream
Length Surveyed
298.6 ft.
Total Length
298.6 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
156
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
157
Pipe schematic from manhole 08 0033 to 08 0032
MH: 08 0033MH: 08 0032downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 003332.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"39.9 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start45 ft. RFJ - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES86.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"138.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"185.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"236.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"285.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"298.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish298.6 ft. AMH - Downstream Manhole, Survey Ends - 08 0032298.6 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK298.6 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (2)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    39.9 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES

    45 ft. - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
298.6CM
298.6AMH08 0032
138.1TF
285.6TFC
185.7TFC
0MWL
32.8TFC
0MWM
298.6MGOCONNECTION AT MH 9 O'CLOCK
298.6MGOCONNECTION AT MH 3 O'CLOCK
45RFJ
0AMH08 0033
236.3TFC
86.6TFC
39.9CM

Properties (6)

additional_info
SC358736
custom_field_two
3
customer
LACSD
datetime
2018-04-13T01:15:23-07:00
documentation
PROPIPE
is_lateral_inspection
false