Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 13, 2018, 06:35 AM
  • 08 0046_08 0045 _12042018_234646.mp4

Date
04/12/2018
W/O
694025
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00016
PipeID
P00048
Time
11:35 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5529
Sewer Name
08 MAIN STREET TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
WO_694025_TV08116_APR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
08 0045
Downstream MH
08 0046
Dir. of Survey
Upstream
Length Surveyed
312.4 ft.
Total Length
312.4 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
186
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
186
Pipe schematic from manhole 08 0045 to 08 0046
MH: 08 0045MH: 08 0046upstream0 ft. AMH - Upstream Manhole, Survey Ends - 08 00460 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish39.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"91.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"143.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"194.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"241.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"294 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"309.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start312.4 ft. AMH - Downstream Manhole, Survey Begins - 08 0045312.4 ft. MWM - Water Mark, 20 %of cross sectional area312.4 ft. MWL - Water Level, 20 %of cross sectional area

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
272.6TFC
220.7TF
0AMH08 0045
312.4AMH08 0046
0MWM
312.4CM
169.3TFC
71TFC
118.3TF
0MWL
18.4TF
3.1CM

Properties (6)

additional_info
SC358736
custom_field_two
3
customer
LACSD
datetime
2018-04-12T23:35:27-07:00
documentation
PROPIPE
is_lateral_inspection
false