Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 12, 2018, 06:05 AM
  • 08 0065_08 0064 _11042018_231958.mp4

Date
04/11/2018
W/O
694025
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00016
PipeID
P00067
Time
11:05 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5528
Sewer Name
08 MAIN STREET TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
WO_694025_TV08116_APR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
08 0064
Downstream MH
08 0065
Dir. of Survey
Upstream
Length Surveyed
328.5 ft.
Total Length
328.5 ft.
Structural Index
4
Structural Quick
4K35
Structural Rating
255
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
255
Pipe schematic from manhole 08 0064 to 08 0065
MH: 08 0064MH: 08 0065upstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 08 00650 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish19.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"70.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"121.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"173.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"212.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"215.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"273.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"300.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start300.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish322.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"325.3 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start328.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK328.5 ft. MWM - Water Mark, 15 %of cross sectional area328.5 ft. MWL - Water Level, 5 %of cross sectional area328.5 ft. AMH - Downstream Manhole, Survey Begins - 08 0064

Observation photos (2)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    3.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    28.4 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (18)

DistanceCodeObservation
309.4TFC
258.3TF
155.2TFC
3.2CM
0MGOCONNECTION AT MH 9 O'CLOCK
328.5MGOCONNECTION AT MH 9 O'CLOCK
115.8TFC
6.2TF
0MWM
207.2TF
328.5AMH08 0065
328.5FM
28.4FM
113TB
0MWL
28.4CM
54.7TFC
0AMH08 0064

Properties (6)

additional_info
SC358735
custom_field_two
2
customer
LACSD
datetime
2018-04-11T23:05:45-07:00
documentation
PROPIPE
is_lateral_inspection
false