Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2016, 09:21 AM
  • 02 0393A_02 0393 _20160810_033756.mp4

Date
08/10/2016
W/O
252431
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00250
PipeID
P02714
Time
2:21 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3679
Sewer Name
02 DOWNEY AVENUE EXTENSION TRUNK
City
PARAMOUNT, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
32
Purpose
Routine Assessment
Project
WO_252431_TV02049_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0393
Downstream MH
02 0393A
Dir. of Survey
Upstream
Length Surveyed
159.5 ft.
Total Length
159.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 0393 to 02 0393A
MH: 02 0393MH: 02 0393Aupstream0 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK ACTIVE0 ft. AMH - Upstream Manhole, Survey Ends - 02 0393A3.7 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish48.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"54.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"95.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"101.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"147.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"152.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"157.3 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start159.5 ft. AMH - Downstream Manhole, Survey Begins - 02 0393159.5 ft. MWM - Water Mark, 15 %of cross sectional area159.5 ft. MWL - Water Level, 10 %of cross sectional area

Observations (13)

DistanceCodeObservation
155.8DAGS
7.2TFC
159.5MGOCONNECTION AT THE MH 3 O'CLOCK ACTIVE
63.7TFC
105.1TFC
12.1TFC
0AMH02 0393
0MWM
2.2DAGS
110.9TFC
58.1TFC
0MWL
159.5AMH02 0393A

Properties (6)

additional_info
SC306009
custom_field_two
4
customer
LACSD
datetime
2016-08-10T02:21:09-07:00
documentation
PRO-PIPE
is_lateral_inspection
false