Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 12, 2016, 09:56 AM
  • 02 0360_A 0101 _20160812_041201.mp4

Date
08/12/2016
W/O
252431
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00250
PipeID
P04548
Time
2:56 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3681
Sewer Name
02 DOWNEY AVENUE EXTENSION TRUNK
City
BELLFLOWER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
38
Purpose
Routine Assessment
Project
WO_252431_TV02049_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0360
Downstream MH
A 0101
Dir. of Survey
Downstream
Length Surveyed
354.8 ft.
Total Length
354.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 02 0360 to A 0101
MH: 02 0360MH: A 0101downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 03600 ft. MWL - Water Level, 5 %of cross sectional area8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"66.7 ft. MWM - Water Mark, 55 %of cross sectional area84.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"147.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"208.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"266.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"354.8 ft. AMH - Downstream Manhole, Survey Ends - A 0101

Observation photos (3)

  • Water Mark, 10 %of cross sectional area

    0 ft. - Water Mark, 10 %of cross sectional area

  • Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"

    8 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"

  • Water Mark, 55 %of cross sectional area

    66.7 ft. - Water Mark, 55 %of cross sectional area

Observations (10)

DistanceCodeObservation
208.8TFC
0MWM
0AMH02 0360
0MWL
147.1TFC
8TFA
66.7MWM
354.8AMHA 0101
84.9TFC
266.3TFC

Properties (6)

additional_info
SC306011
custom_field_two
4
customer
LACSD
datetime
2016-08-12T02:56:00-07:00
documentation
PRO-PIPE
is_lateral_inspection
false