Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 8, 2016, 08:48 AM
  • 02 0384_02 0383 _20160808_030635.mp4

Date
08/08/2016
W/O
252431
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00250
PipeID
P02702
Time
1:48 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3677
Sewer Name
02 DOWNEY AVENUE EXTENSION TRUNK
City
BELLFLOWER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
36
Purpose
Routine Assessment
Project
WO_252431_TV02049_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0384
Downstream MH
02 0383
Dir. of Survey
Downstream
Length Surveyed
313.1 ft.
Total Length
313.1 ft.
Structural Index
3
Structural Quick
3500
Structural Rating
15
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
17
Pipe schematic from manhole 02 0384 to 02 0383
MH: 02 0384MH: 02 0383downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 03842.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start13 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"16.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"33.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES56.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"63.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4", 4"95 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"118.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"125.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"131.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES157.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"168.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"179.6 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"188.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"219.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"223.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"250.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"252.7 ft. CM - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES263.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES278.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"280.6 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES294.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"310.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish313.1 ft. AMH - Downstream Manhole, Survey Ends - 02 0383313.1 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK ACTIVE

Observation photos (7)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    33.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"

    118.3 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    131.1 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

    252.7 ft. - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    263.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    280.6 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (28)

DistanceCodeObservation
263.8CM
179.6TBA
0MWL
223.2TFA
280.6CM
16.3TF
95TF
294.2TFC
250.8TFA
219.9TFA
2.6DAGS
313.1AMH02 0383
0MWM
278.5TFA
0AMH02 0384
310.5DAGS
56.2TF
313.1MGOCONNECTION AT THE MH 3 O'CLOCK ACTIVE
168.9TFC
63.1TFC
252.7CM
33.4CM
157.3TFA
131.1CM
13TFC
188.3TFC
118.3TF
125.9TFA