Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 10, 2019, 09:56 AM
  • Section#6_18 0971_18 0970__7102019__I0172.mp4

Date
07/10/2019
W/O
0777340
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00716
PipeID
P14821
Time
2:56 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0172
Sewer Name
18 WORSHAM CREEK TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
11
Purpose
Resurvey For Any Reason
Project
20191007VMR_WORSHAM_CREEK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
7.519999980926514 in.
Upstream MH
18 0971
Downstream MH
18 0970
Dir. of Survey
Downstream
Length Surveyed
325 ft.
Total Length
325 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
1
Overall Quick
Overall Rating
2
Pipe schematic from manhole 18 0971 to 18 0970
MH: 18 0971MH: 18 0970downstream0 ft. AMH - Upstream Manhole, Survey Begins - 04:42 AM0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area59.9 ft. RFC - Roots Fine Connection, at 11 o'clock, within 8 inches of joint: NO80.5 ft. RFC - Roots Fine Connection, from 11 to 12 o'clock, within 8 inches of joint: NO325 ft. AMH - Downstream Manhole, Survey Ends - 05:05 AM

Observation photos (2)

  • Roots Fine Connection, at 11 o'clock, within 8 inches of joint: NO

    59.9 ft. - Roots Fine Connection, at 11 o'clock, within 8 inches of joint: NO

  • Roots Fine Connection, from 11 to 12 o'clock, within 8 inches of joint: NO

    80.5 ft. - Roots Fine Connection, from 11 to 12 o'clock, within 8 inches of joint: NO

Observations (6)

DistanceCodeObservation
59.9RFC
80.5RFC
325AMH05:05 AM
0AMH04:42 AM
0MWM
0MWL

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-07-10T02:56:05-07:00
is_lateral_inspection
false
lining
PVCP-Folded/Reformed