- Date
- 09/14/2017
- W/O
- 651629
- Weather
- Dry
- Operator/Surveyor
- JUAN B
- Sewer ID
- Z00035
- PipeID
- P10152
- Time
- 2:38 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K4971
- Sewer Name
- F JOINT OUTFALL F - UNIT 3A
- City
- BELLFLOWER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 39
- Purpose
- Routine Assessment
- Project
- WO_651629_TV02199_AUG2017
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 60 in.
- Width
- 60 in.
- Upstream MH
- F 0067
- Downstream MH
- F 0066
- Dir. of Survey
- Downstream
- Length Surveyed
- 630 ft.
- Total Length
- 630 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 3
- O&M Quick
- 4121
- O&M Rating
- 6
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 9
Pipe schematic from manhole F 0067 to F 0066 Observation photos (2)

10.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

10.1 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start