Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 14, 2017, 08:15 AM
  • 02 1235_02 1234_14072017_011612.mp4

Date
07/14/2017
W/O
646743
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00303
PipeID
P18787
Time
1:15 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4649
Sewer Name
02 SANTA ANITA OUTFALL TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
14
Purpose
Routine Assessment
Project
WO_646743_TV02300_JUL2017
Sewer Type
Siphon
Material
CIP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 1234
Downstream MH
02 1235
Dir. of Survey
Upstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 02 1234 to 02 1235
MH: 02 1234MH: 02 1235upstream0 ft. MSA - Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH0 ft. SCP - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: NO2.1 ft. AMH - Downstream Manhole, Survey Begins - 02 1234 W2.1 ft. MWM - Water Mark, 20 %of cross sectional area2.1 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (2)

  • Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH

    2.1 ft. - Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH

  • Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: NO

    2.1 ft. - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: NO

Observations (5)

DistanceCodeObservation
0AMH02 1234 W
0MWM
2.1MSAVIEW OF U/S SIPHON FROM D/S MH
2.1SCP
0MWL

Properties (6)

additional_info
SC345509
custom_field_two
3
customer
LACSD
datetime
2017-07-14T01:15:55-07:00
documentation
PROPIPE
is_lateral_inspection
false