Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 31, 2016, 11:25 AM
  • 15 0977_15 0976_31032016_042613.mp4

Date
03/31/2016
W/O
563410
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00636
PipeID
P12752
Time
4:25 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3302
Sewer Name
15 VALINDA TRUNK
City
INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
34
Purpose
Routine Assessment
Project
WO_563410_TV15038_APRIL2016
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
15 0977
Downstream MH
15 0976
Dir. of Survey
Downstream
Length Surveyed
346.9 ft.
Total Length
346.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2M00
O&M Rating
136
Overall Index
2
Overall Quick
Overall Rating
136
Pipe schematic from manhole 15 0977 to 15 0976
MH: 15 0977MH: 15 0976downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 09770 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start41.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"102 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"158.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"234.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"296 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"344.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish346.9 ft. MGO - General Observation - CAPPED CONNECTION AT MH 9 O'CLOCK346.9 ft. AMH - Downstream Manhole, Survey Ends - 15 0976346.9 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (3)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    346.9 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (14)

DistanceCodeObservation
296TF
346.9MGOCAPPED CONNECTION AT MH 9 O'CLOCK
0AMH15 0977
0MGOCOCKROACHES IN MANHOLE
41.1TF
346.9AMH15 0976
2DAGS
234.9TFC
344.1DAGS
346.9MGOCOCKROACHES IN MANHOLE
0MWL
158.2TFA
0MWM
102TFC

Properties (6)

additional_info
SC305428
custom_field_two
4
customer
LACSD
datetime
2016-03-31T04:25:59-07:00
documentation
PRO PIPE
is_lateral_inspection
false