Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 30, 2015, 08:47 AM
  • 02 1298_02 1297_30102015_014826.mp4

Date
10/30/2015
W/O
521098
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00238
PipeID
P03815
Time
1:47 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2819
Sewer Name
02 BELVEDERE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
WO_521098_TV02329_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
02 1297
Downstream MH
02 1298
Dir. of Survey
Upstream
Length Surveyed
292.2 ft.
Total Length
292.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2K00
O&M Rating
116
Overall Index
2
Overall Quick
Overall Rating
116
Pipe schematic from manhole 02 1297 to 02 1298
MH: 02 1297MH: 02 1298upstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 12 O'CLOCK0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Ends - 02 12981 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish96 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"98.2 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"105.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"119.4 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"138.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"144 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"151.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"217.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"219.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"253.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"257.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"275 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"290.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start292.2 ft. MGO - General Observation - COCKROACHES IN MANHOLE292.2 ft. AMH - Downstream Manhole, Survey Begins - 02 1297292.2 ft. MWL - Water Level, 10 %of cross sectional area292.2 ft. MWM - Water Mark, 25 %of cross sectional area

Observations (21)

DistanceCodeObservation
34.5TFA
74.9TFA
140.7TFA
292.2MGOACTIVE CONNECTION AT MH 12 O'CLOCK
292.2MGOCOCKROACHES IN MANHOLE
186.3TF
39TFA
17.2TFA
0MGOCOCKROACHES IN MANHOLE
0AMH02 1297
0MWL
292.2AMH02 1298
0MWM
172.8TB
2DAGS
196.2TFC
72.4TFA
153.4TFC
291.2DAGS
148.2TF
194TFC

Properties (6)

additional_info
SC204151
custom_field_two
4
customer
LACSD
datetime
2015-10-30T01:47:52-07:00
documentation
PRO PIPE
is_lateral_inspection
false