Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 1, 2017, 07:43 AM
  • 19 0271_19 0073 _01092017_005853.mp4

Date
09/01/2017
W/O
651801
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00732
PipeID
P15241
Time
12:43 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4704
Sewer Name
19 209TH STREET TRUNK
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
06
Purpose
Routine Assessment
Project
WO_651801_TV19001_AUG2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
19 0271
Downstream MH
19 0073
Dir. of Survey
Downstream
Length Surveyed
220.9 ft.
Total Length
220.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
3122
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 19 0271 to 19 0073
MH: 19 0271MH: 19 0073downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 19 02710 ft. MWL - Water Level, 15 %of cross sectional area4.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start7 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start9.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start12.8 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"15.7 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"70.7 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"74 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"123 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"126.2 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"172.9 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"175.3 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"209.3 ft. OBJ - Obstacles In Joint, 20 %of cross sectional area, from 04 to 08 o'clock - UNKNOWN220.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish220.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish220.9 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish220.9 ft. AMH - Downstream Manhole, Survey Ends - 19 0073

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    4.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    7 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    9.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (19)

DistanceCodeObservation
15.7TF
7DAE
220.9DAGS
175.3TF
12.8TFC
220.9CM
4.7DAGS
0MWM
123TFC
0AMH19 0271
220.9DAE
0MWL
74TF
70.7TFC
172.9TFC
220.9AMH19 0073
209.3OBJUNKNOWN
9.4CM
126.2TF

Properties (6)

additional_info
SC345645
custom_field_two
3
customer
LACSD
datetime
2017-09-01T00:43:35-07:00
documentation
PROPIPE
is_lateral_inspection
false