Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 1, 2017, 06:56 AM
  • 19 0276_19 0275 _01092017_001058.mp4

Date
08/31/2017
W/O
651801
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00732
PipeID
P15246
Time
11:56 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4704
Sewer Name
19 209TH STREET TRUNK
City
LAKEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
07
Purpose
Routine Assessment
Project
WO_651801_TV19001_AUG2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
19 0275
Downstream MH
19 0276
Dir. of Survey
Upstream
Length Surveyed
5 ft.
Total Length
5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 19 0275 to 19 0276
MH: 19 0275MH: 19 0276upstream0 ft. MGO - General Observation - CONNECTION AT 3 OC0 ft. MGO - General Observation - END OF LINE0 ft. AMH - Upstream Manhole, Survey Ends - 19 02752.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES5 ft. MWM - Water Mark, 20 %of cross sectional area5 ft. MWL - Water Level, 10 %of cross sectional area5 ft. AMH - Downstream Manhole, Survey Begins - 19 0275

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES

    2.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES

  • General Observation - END OF LINE

    5 ft. - General Observation - END OF LINE

Observations (7)

DistanceCodeObservation
0MWM
2.6DAGS
5MGOCONNECTION AT 3 OC
5MGOEND OF LINE
0MWL
5AMH19 0275
0AMH19 0275

Properties (6)

additional_info
SC345645
custom_field_two
3
customer
LACSD
datetime
2017-08-31T23:56:31-07:00
documentation
PROPIPE
is_lateral_inspection
false