Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 26, 2017, 11:50 PM
  • 18 0828_18 0827 _30082017_164227.mp4

Date
07/26/2017
W/O
651582
Weather
Dry
Operator/Surveyor
COREY D
Sewer ID
Z00707
PipeID
P14691
Time
4:50 PM
Certificate
U-912-159863
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4783
Sewer Name
18 SO WHITTIER OUTFALL TR, SECT 5
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
WO_651582_TV18113_AUG2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0828
Downstream MH
18 0827
Dir. of Survey
Downstream
Length Surveyed
283.2 ft.
Total Length
283.2 ft.
Structural Index
4
Structural Quick
4J31
Structural Rating
219
O&M Index
2
O&M Quick
2J00
O&M Rating
112
Overall Index
3
Overall Quick
Overall Rating
331
Pipe schematic from manhole 18 0828 to 18 0827
MH: 18 0828MH: 18 0827downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 08280 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start6.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES9.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES19 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start42 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 4"44.1 ft. MGO - General Observation - UNMAPPED MH STRUCTURE63.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"66.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"113.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"116 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"163 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"165.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"212.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"215 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"264 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"267 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"282.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish282.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish283.2 ft. AMH - Downstream Manhole, Survey Ends - 18 0827

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    6.1 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    9.1 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    19 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (22)

DistanceCodeObservation
165.1TFC
0AMH18 0828
6.1FM
44.1MGOUNMAPPED MH STRUCTURE
42TB
282.1FM
163TFC
19FM
282.1DAGS
9.1CM
267TFC
2.1DAGS
113.1TFC
0MWM
283.2AMH18 0827
212.1TFC
116TFC
66.1TFC
0MWL
215TFC
264TFC
63.1TFC

Properties (6)

additional_info
SC344613
custom_field_two
3
customer
LACSD
datetime
2017-07-26T16:50:45-07:00
documentation
PROPIPE
is_lateral_inspection
false