Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 26, 2017, 11:50 PM
  • 18 0824_18 0823 _29082017_125827.mp4

Date
07/26/2017
W/O
651582
Weather
Dry
Operator/Surveyor
COREY D
Sewer ID
Z00707
PipeID
P14687
Time
4:50 PM
Certificate
U-912-159863
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4783
Sewer Name
18 SO WHITTIER OUTFALL TR, SECT 5
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
WO_651582_TV18113_AUG2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0824
Downstream MH
18 0823
Dir. of Survey
Downstream
Length Surveyed
333 ft.
Total Length
333 ft.
Structural Index
4
Structural Quick
4L00
Structural Rating
264
O&M Index
2
O&M Quick
2M00
O&M Rating
136
Overall Index
3
Overall Quick
Overall Rating
400
Pipe schematic from manhole 18 0824 to 18 0823
MH: 18 0824MH: 18 0823downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 08240 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area1.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES4.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start35 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 4"50 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"91.1 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4"102 ft. TBI - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 4", 2"150 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 4"153.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 4"201 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 4"213 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 4"253.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 4"273 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"305 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 4"328.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 4"330 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish330 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish333 ft. AMH - Downstream Manhole, Survey Ends - 18 0823

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    1.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    2.1 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    4.1 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 4", 2"

    102 ft. - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 4", 2"

Observations (21)

DistanceCodeObservation
330FM
305TB
328.1TB
201TB
35TB
150TB
253.1TB
91.1TF
4.1FM
273TF
0AMH18 0824
102TBI
333AMH18 0823
0MWL
330DAGS
153.1TB
50TBC
1.1DAGS
2.1FM
213TB
0MWM

Properties (6)

additional_info
SC344613
custom_field_two
3
customer
LACSD
datetime
2017-07-26T16:50:43-07:00
documentation
PROPIPE
is_lateral_inspection
false