Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 5, 2017, 10:37 AM
  • A 1138_A 1137 _05092017_033958.mp4

Date
09/05/2017
W/O
651775
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00973
PipeID
P02789
Time
3:37 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4957
Sewer Name
A JOINT OUTFALL A - UNIT 9
City
PARAMOUNT
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
31
Purpose
Routine Assessment
Project
WO_651775_TV02134_AUG2017
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
42 in.
Upstream MH
A 1137
Downstream MH
A 1138
Dir. of Survey
Upstream
Length Surveyed
5 ft.
Total Length
5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
5121
O&M Rating
7
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole A 1137 to A 1138
MH: A 1137MH: A 1138upstream0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES0 ft. MSA - Survey Abandoned - SIPHON UPLEG5 ft. MWL - Water Level, 50 %of cross sectional area5 ft. AMH - Downstream Manhole, Survey Begins - A 11375 ft. MWM - Water Mark, 75 %of cross sectional area5 ft. MGO - General Observation - ACTIVE CONNECTION INSIDE THE MH. @ 03 O'CLOCK

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock,  , within 8 inches of joint: YES

    5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES

  • Survey Abandoned - SIPHON UPLEG

    5 ft. - Survey Abandoned - SIPHON UPLEG

Observations (6)

DistanceCodeObservation
0MWL
0AMHA 1137
5DAGS
0MWM
0MGOACTIVE CONNECTION INSIDE THE MH. @ 03 O'CLOCK
5MSASIPHON UPLEG

Properties (6)

additional_info
SC345648
custom_field_two
3
customer
LACSD
datetime
2017-09-05T03:37:27-07:00
documentation
PROPIPE
is_lateral_inspection
false