Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 20, 2015, 11:20 AM
  • 22 1392_22 1391_20150420_043011.mp4

Date
04/20/2015
W/O
496785
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00795
PipeID
P16649
Time
4:20 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2358
Sewer Name
22 CAMERON RELIEF TRUNK
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
31
Purpose
Routine Assessment
Project
WO_496785_TV22009_2015MARCH
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
22 1392
Downstream MH
22 1391
Dir. of Survey
Downstream
Length Surveyed
275 ft.
Total Length
275 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 22 1392 to 22 1391
MH: 22 1392MH: 22 1391downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 13920 ft. MWM - Water Mark, 20 %of cross sectional area1.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start158.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"272.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish275 ft. AMH - Downstream Manhole, Survey Ends - 22 1391

Observation photos (6)

  • Water Level, 10 %of cross sectional area

    0 ft. - Water Level, 10 %of cross sectional area

  • Upstream Manhole, Survey Begins - 22 1392

    0 ft. - Upstream Manhole, Survey Begins - 22 1392

  • Water Mark, 20 %of cross sectional area

    0 ft. - Water Mark, 20 %of cross sectional area

  • Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Start

    1.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    158.4 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Downstream Manhole, Survey Ends - 22 1391

    275 ft. - Downstream Manhole, Survey Ends - 22 1391

Observations (7)

DistanceCodeObservation
0MWL
158.4TF
1.1DAGS
275AMH22 1391
0AMH22 1392
0MWM
272.7DAGS

Properties (6)

additional_info
200711
custom_field_two
4
customer
LACSD
datetime
2015-04-20T04:20:01-07:00
is_lateral_inspection
false
year_laid
19900530