Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 24, 2016, 08:59 AM
  • 18 0878_18 0877_062416_020000.mpg

Date
06/24/2016
W/O
574406
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00709
PipeID
P14729
Time
1:59 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3405
Sewer Name
18 SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
31
Purpose
Routine Assessment
Project
WO_574406_TV18102_JUNE2016
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Upstream MH
18 0878
Downstream MH
18 0877
Dir. of Survey
Downstream
Length Surveyed
253.8 ft.
Total Length
253.8 ft.
Structural Index
3
Structural Quick
3F00
Structural Rating
99
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
99
Pipe schematic from manhole 18 0878 to 18 0877
MH: 18 0878MH: 18 0877downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 08780 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK88.2 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start253.8 ft. AMH - Downstream Manhole, Survey Ends - 18 0877253.8 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK253.8 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    88.2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0AMH18 0878
253.8AMH18 0877
0MWL
253.8MGOCONNECTION AT THE MH 9 O'CLOCK
0MWM
88.2SAV
0MGOCONNECTION AT THE MH 9 O'CLOCK
253.8SAV

Properties (6)

additional_info
SC305855
custom_field_two
3
customer
LACSD
datetime
2016-06-24T01:59:26-07:00
documentation
PROPIPE
is_lateral_inspection
false