Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 8, 2017, 03:08 PM
  • C 0312_C 0311A_782017_133036.mp4

Date
07/08/2017
W/O
0650313
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00135
PipeID
P09773
Time
8:08 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
H0585
Sewer Name
C JOINT OUTFALL C - UNIT 6F
City
CERRITOS
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Resurvey For Any Reason
Project
20170708VMR_JOINT_OUTFALL_C_UNIT_6F
Material
Reinforced Concrete Pipe
Shape
Circular
Height
15 in.
Upstream MH
C 0312
Downstream MH
C 0311A
Dir. of Survey
Downstream
Length Surveyed
175 ft.
Total Length
175 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole C 0312 to C 0311A
MH: C 0312MH: C 0311Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 12:30 pm0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 30 %of cross sectional area166 ft. MGP - General Photograph - calcium Deposit before cleaning172.9 ft. MGP - General Photograph - After cleaning175 ft. MSA - Survey Abandoned - Calcium removed

Observation photos (2)

  • General Photograph - calcium Deposit before cleaning

    166 ft. - General Photograph - calcium Deposit before cleaning

  • General Photograph - After cleaning

    172.9 ft. - General Photograph - After cleaning

Observations (6)

DistanceCodeObservation
0AMH12:30 pm
175MSACalcium removed
0MWM
172.9MGPAfter cleaning
166MGPcalcium Deposit before cleaning
0MWL

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2017-07-08T08:08:32-07:00
documentation
REVELES, OLIVER III
is_lateral_inspection
false