Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 20, 2017, 09:02 AM
  • 15 0136_15 0135 _20062017_021257.mpg

Date
06/20/2017
W/O
624421
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00634
PipeID
P12035
Time
2:02 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4622
Sewer Name
15 TYLER AVENUE TRUNK
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
23
Purpose
Routine Assessment
Project
WO_624421_TV15037_JUN2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
15 0136
Downstream MH
15 0135
Dir. of Survey
Downstream
Length Surveyed
306.6 ft.
Total Length
306.6 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 15 0136 to 15 0135
MH: 15 0136MH: 15 0135downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 01360 ft. MGO - General Observation - CONNECTION AT MH 6 O'CLOCK0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area2.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.2 ft. MGO - General Observation - MAG COAT127.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"260.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 10 o'clock, , within 8 inches of joint: YES262.2 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"306.6 ft. AMH - Downstream Manhole, Survey Ends - 15 0135306.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 08 to 10 o'clock,  , within 8 inches of joint: YES

    260.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 10 o'clock, , within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
127.3TFA
306.6AMH15 0135
260.9DAGS
262.2TFA
0AMH15 0136
306.6SAV
2.2SAV
0MGOCONNECTION AT MH 6 O'CLOCK
0MWM
0MWL
2.2MGOMAG COAT

Properties (6)

additional_info
SC345337
custom_field_two
3
customer
LACSD
datetime
2017-06-20T02:02:43-07:00
documentation
PROPIPE
is_lateral_inspection
false