Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 27, 2017, 09:31 AM
  • 15 0935_15 0123 _27062017_023716.mp4

Date
06/27/2017
W/O
624421
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00634
PipeID
P12022
Time
2:31 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4594
Sewer Name
15 TYLER AVENUE TRUNK
City
EL M0NTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
23
Purpose
Routine Assessment
Project
WO_624421_TV15037_JUN2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
15 0123
Downstream MH
15 0935
Dir. of Survey
Upstream
Length Surveyed
72 ft.
Total Length
72 ft.
Structural Index
3
Structural Quick
3B00
Structural Rating
42
O&M Index
2
O&M Quick
2B00
O&M Rating
28
Overall Index
3
Overall Quick
Overall Rating
70
Pipe schematic from manhole 15 0123 to 15 0935
MH: 15 0123MH: 15 0935upstream0 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 15 09350 ft. MGO - General Observation - COCKROACHES IN MANHOLE70 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start70 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start72 ft. MWL - Water Level, 10 %of cross sectional area72 ft. MWM - Water Mark, 15 %of cross sectional area72 ft. MGO - General Observation - COCKROACHES IN MANHOLE72 ft. AMH - Downstream Manhole, Survey Begins - 15 0123

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0MWL
0MWM
2SAV
2DAGS
0MGOCOCKROACHES IN MANHOLE
72SAV
0AMH15 0123
72DAGS
72AMH15 0935
72MGOCOCKROACHES IN MANHOLE

Properties (6)

additional_info
SC345342
custom_field_two
3
customer
LACSD
datetime
2017-06-27T02:31:24-07:00
documentation
PRO PIPE
is_lateral_inspection
false