Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 30, 2017, 09:16 AM
  • 02 1757A_02 1757 _30112017_011708.mp4

Date
11/30/2017
W/O
674573
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00254
PipeID
P04102
Time
1:16 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5055
Sewer Name
02 DOWNEY-BELLFLOWER EXTENSION TRUNK
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
15
Purpose
Routine Assessment
Project
WO_674573_TV02052_DEC2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
02 1757A
Downstream MH
02 1757
Dir. of Survey
Downstream
Length Surveyed
182.1 ft.
Total Length
182.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4E33
O&M Rating
199
Overall Index
3
Overall Quick
Overall Rating
199
Pipe schematic from manhole 02 1757A to 02 1757
MH: 02 1757AMH: 02 1757downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 1757A0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK1.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start4.1 ft. RFJ - Roots Fine Joint, from 07 to 05 o'clock, within 8 inches of joint: YES, Start33.4 ft. RFJ - Roots Fine Joint, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish33.5 ft. RMJ - Roots Medium Joint, from 07 to 05 o'clock, 25 %, within 8 inches of joint: YESR, Start48.3 ft. RMJ - Roots Medium Joint, from 07 to 05 o'clock, 25 %, within 8 inches of joint: YESR, Finish48.3 ft. RBJ - Roots Ball Joint, from 07 to 05 o'clock, 85 %, within 8 inches of joint: YES51.4 ft. RBJ - Roots Ball Joint, from 07 to 05 o'clock, 75 %, within 8 inches of joint: YES, Start96.1 ft. RBJ - Roots Ball Joint, from 08 to 05 o'clock, 90 %, within 8 inches of joint: YES106.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"166.9 ft. MGO - General Observation - PAUSED VIDEO TO CLEAN LENS RESTARTED ON WRONG LINE182.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish182.1 ft. MSA - Survey Abandoned - CAM BLKD BY ROOTS182.1 ft. RBJ - Roots Ball Joint, from 07 to 05 o'clock, 75 %, within 8 inches of joint: YES, Finish

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Start

    1.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

  • Roots Medium Joint, from 07 to 05 o'clock, 25 %, within 8 inches of joint: YESR, Start

    33.5 ft. - Roots Medium Joint, from 07 to 05 o'clock, 25 %, within 8 inches of joint: YESR, Start

  • Roots Ball Joint, from 07 to 05 o'clock, 85 %, within 8 inches of joint: YES

    48.3 ft. - Roots Ball Joint, from 07 to 05 o'clock, 85 %, within 8 inches of joint: YES

  • Roots Ball Joint, from 07 to 05 o'clock, 75 %, within 8 inches of joint: YES, Start

    51.4 ft. - Roots Ball Joint, from 07 to 05 o'clock, 75 %, within 8 inches of joint: YES, Start

  • Roots Ball Joint, from 08 to 05 o'clock, 90 %, within 8 inches of joint: YES

    96.1 ft. - Roots Ball Joint, from 08 to 05 o'clock, 90 %, within 8 inches of joint: YES

  • Roots Ball Joint, from 07 to 05 o'clock, 75 %, within 8 inches of joint: YES, Finish

    182.1 ft. - Roots Ball Joint, from 07 to 05 o'clock, 75 %, within 8 inches of joint: YES, Finish

Observations (17)

DistanceCodeObservation
96.1RBJ
166.9MGOPAUSED VIDEO TO CLEAN LENS RESTARTED ON WRONG LINE
106.9TF
48.3RMJ
1.9DAGS
0MWL
0AMH02 1757A
0MWM
182.1DAGS
48.3RBJ
4.1RFJ
33.4RFJ
182.1MSACAM BLKD BY ROOTS
33.5RMJ
0MGOCONNECTION AT MH 3 O'CLOCK
51.4RBJ
182.1RBJ

Properties (6)

additional_info
SC346284
custom_field_two
3
customer
LACSD
datetime
2017-11-30T01:16:53-08:00
documentation
PROPIPE
is_lateral_inspection
false