Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 28, 2017, 11:46 AM
  • C 0394A_C 0394 _11282017_034706.mp4

Date
11/28/2017
W/O
674250
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00143
PipeID
P09862
Time
3:46 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5231
Sewer Name
C JOINT OUTFALL C - UNIT 8E
City
CERRITOS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
WO_674250_TV02139_DEC2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
C 0394A
Downstream MH
C 0394
Dir. of Survey
Downstream
Length Surveyed
28.1 ft.
Total Length
28.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4122
O&M Rating
8
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole C 0394A to C 0394
MH: C 0394AMH: C 0394downstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 0394A2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 08 o'clock, , within 8 inches of joint: YES, Start25.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 08 o'clock, , within 8 inches of joint: YES, Finish28.1 ft. AMH - Downstream Manhole, Survey Ends - C 0394

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
0MWM
0MWL
0AMHC 0394A
25.2DAGS
28.1AMHC 0394
2DAGS

Properties (7)

additional_info
SC346402
custom_field_two
4
customer
LACSD
datetime
2017-11-28T03:46:45-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
26597