Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 21, 2017, 10:45 AM
  • 18 0667_18 0666 _21112017_024615.mpg

Date
11/21/2017
W/O
668744
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00696
PipeID
P14516
Time
2:45 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5042
Sewer Name
18 PHOEBE AVENUE TRUNK
City
LA MIRADA, CA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
36
Purpose
Routine Assessment
Project
WO_668744_TV18081_NOV2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
18 0667
Downstream MH
18 0666
Dir. of Survey
Downstream
Length Surveyed
335.8 ft.
Total Length
335.8 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 18 0667 to 18 0666
MH: 18 0667MH: 18 0666downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 06670 ft. MGO - General Observation - SERVICE CONNECTION AT 3 O' CLOCK AT MH49.3 ft. CM - Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES, Start74 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"121.3 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"179.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"275.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"335.8 ft. CM - Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES, Finish335.8 ft. AMH - Downstream Manhole, Survey Ends - 18 0666

Observation photos (1)

  • Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES, Start

    49.3 ft. - Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
74TFC
0MWM
275.4TFC
0MWL
335.8CM
335.8AMH18 0666
49.3CM
0AMH18 0667
121.3TFA
0MGOSERVICE CONNECTION AT 3 O' CLOCK AT MH
179.9TF

Properties (6)

additional_info
SC346271
custom_field_two
3
customer
LACSD
datetime
2017-11-21T02:45:41-08:00
documentation
PRO-PIPE
is_lateral_inspection
false