Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 5, 2016, 09:10 AM
  • 05 1893_05 1892 _05082016_021215.mp4

Date
08/05/2016
W/O
579954
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00491
PipeID
P07120
Time
2:10 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3627
Sewer Name
05 NARBONNE AVENUE TRUNK, SECTION 2
City
ROLLING HILLS ESTATES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
40
Purpose
Routine Assessment
Project
WO_579954_TV05079_JULY2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1893
Downstream MH
05 1892
Dir. of Survey
Downstream
Length Surveyed
280.3 ft.
Total Length
280.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3221
O&M Rating
11
Overall Index
2
Overall Quick
Overall Rating
11
Pipe schematic from manhole 05 1893 to 05 1892
MH: 05 1893MH: 05 1892downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 18930 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 5 %of cross sectional area31 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"33.8 ft. RFJ - Roots Fine Joint, from 08 to 02 o'clock, within 8 inches of joint: YESR45.8 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start60 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"71.3 ft. TBD - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: NO, 6" - ROOTS119.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"155.1 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS155.2 ft. RML - Roots Medium Lateral, from 06 to 11 o'clock, 15 %, within 8 inches of joint: YES206.1 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"227 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"278.5 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Finish280.3 ft. AMH - Downstream Manhole, Survey Ends - 05 1892

Observation photos (5)

  • Roots Fine Joint, from 08 to 02 o'clock, within 8 inches of joint: YESR

    33.8 ft. - Roots Fine Joint, from 08 to 02 o'clock, within 8 inches of joint: YESR

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start

    45.8 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start

  • Tap Break-In Defective, at 10 o'clock, -,  , within 8 inches of joint: NO, 6" - ROOTS

    71.3 ft. - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: NO, 6" - ROOTS

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

    155.1 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

  • Roots Medium Lateral, from 06 to 11 o'clock, 15 %, within 8 inches of joint: YES

    155.2 ft. - Roots Medium Lateral, from 06 to 11 o'clock, 15 %, within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
278.5RFJ
33.8RFJ
31TFA
119.8TFA
280.3AMH05 1892
155.1TFDROOTS
0AMH05 1893
227TFC
206.1TBA
45.8RFJ
71.3TBDROOTS
60TFC
155.2RML
0MWL
0MWM

Properties (6)

additional_info
SC306061
custom_field_two
4
customer
LACSD
datetime
2016-08-05T02:10:15-07:00
documentation
PRO PIPE
is_lateral_inspection
false