Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 23, 2016, 10:36 AM
  • 04 0083A_04 0083_23022016_023656.mp4

Date
02/23/2016
W/O
552531
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00415
PipeID
P11822
Time
2:36 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3264
Sewer Name
04 SHERMAN TRUNK
City
WEST HOLLYWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 04
Page No.
01
Purpose
Routine Assessment
Project
WO_552531_TV04009_FEB2016
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Lining Method
Segmented Panel
Shape
Circular
Height
12 in.
Upstream MH
04 0083A
Downstream MH
04 0083
Dir. of Survey
Downstream
Length Surveyed
129.7 ft.
Total Length
129.7 ft.
Structural Index
3
Structural Quick
4232
Structural Rating
18
O&M Index
2
O&M Quick
2D00
O&M Rating
52
Overall Index
2
Overall Quick
Overall Rating
70
Pipe schematic from manhole 04 0083A to 04 0083
MH: 04 0083AMH: 04 0083downstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 04 0083A0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 8 O'CLOCK0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 2 O'CLOCK2 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start5.5 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES33.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"53.8 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES78.4 ft. FM - Fracture Multiple, from 03 to 11 o'clock, within 8 inches of joint: YES, Start80.2 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"83.4 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"90.3 ft. FM - Fracture Multiple, from 03 to 11 o'clock, within 8 inches of joint: YES, Finish90.3 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"104.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"110 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"127.7 ft. CM - Crack Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES129.2 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"129.7 ft. AMH - Downstream Manhole, Survey Ends - 04 0083, CONNECTION NODE129.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (7)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    2 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    5.5 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    53.8 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 03 to 11 o'clock, within 8 inches of joint: YES, Start

    78.4 ft. - Fracture Multiple, from 03 to 11 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

    127.7 ft. - Crack Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
5.5CM
0MGOCOCKROACHES IN MANHOLE
110TFC
83.4TFA
80.2TFA
78.4FM
0AMH04 0083A
90.3FM
0MGOACTIVE CONNECTION AT MH 8 O'CLOCK
129.2TFA
129.7AMH04 0083, CONNECTION NODE
90.3TBA
2CL
104.1TFC
2DAGS
0MGOACTIVE CONNECTION AT MH 2 O'CLOCK
53.8CL
129.7DAGS
127.7CM
33.3TFA

Properties (6)

additional_info
SC225487
custom_field_two
4
customer
LACSD
datetime
2016-02-23T02:36:38-08:00
documentation
PRO PIPE
is_lateral_inspection
false