Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 23, 2017, 06:01 PM
  • 19 0180_19 0179_12232017_130125.mp4

Date
12/23/2017
W/O
0650319
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00719
PipeID
P15148
Time
10:01 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7588
Sewer Name
19 CERRITOS TRUNK
City
CERRITOS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
05
Purpose
Routine Assessment
Project
20171223DF_CERRITOS_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
19 0180
Downstream MH
19 0179
Dir. of Survey
Downstream
Length Surveyed
349.2 ft.
Total Length
349.2 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
2
O&M Quick
2300
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole 19 0180 to 19 0179
MH: 19 0180MH: 19 0179downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:59 PM0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 11 o'clock, , within 8 inches of joint: YES96.2 ft. MGP - General Photograph212.2 ft. MGP - General Photograph224.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES316.3 ft. MGP - General Photograph347 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish347.1 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 02 to 04 o'clock, , within 8 inches of joint: YES349.1 ft. MGO - General Observation - Grease Throughout The Reach (5%)349.2 ft. AMH - Downstream Manhole, Survey Ends - 1:17 PM

Observation photos (7)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 11 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 11 o'clock, , within 8 inches of joint: YES

  • General Photograph

    96.2 ft. - General Photograph

  • General Photograph

    212.2 ft. - General Photograph

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 11 o'clock,  , within 8 inches of joint: YES

    224.1 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES

  • General Photograph

    316.3 ft. - General Photograph

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 02 to 04 o'clock,  , within 8 inches of joint: YES

    347.1 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 02 to 04 o'clock, , within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
316.3MGP
0MWL
0AMH12:59 PM
224.1DAE
2SSS
349.1MGOGrease Throughout The Reach (5%)
347SSS
212.2MGP
96.2MGP
2DAE
0MWM
349.2AMH1:17 PM
347.1DAE

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2017-12-23T10:01:29-08:00
documentation
FRANKLIN, BRAR
is_lateral_inspection
false