Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 21, 2017, 10:21 AM
  • Section#4_08 0003_08 0002__12212017__G6889.mp4

Date
12/21/2017
W/O
0679385
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00016
PipeID
P00103
Time
2:21 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6889
Sewer Name
08 MAIN STREET TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Capital Improvement Program Assesment
Project
20171221MDM_MAIN_STREET_TRUNK
Material
RCP-CTL
Shape
Circular
Height
33 in.
Upstream MH
08 0003
Downstream MH
08 0002
Dir. of Survey
Downstream
Length Surveyed
275.6 ft.
Total Length
275.6 ft.
Structural Index
5
Structural Quick
5K4J
Structural Rating
520
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
5
Overall Quick
Overall Rating
525
Pipe schematic from manhole 08 0003 to 08 0002
MH: 08 0003MH: 08 0002downstream0 ft. MGO - General Observation - MH CONN 9:00 OPEN0 ft. AMH - Upstream Manhole, Survey Begins - 4:50AM0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MWM - Water Mark, 80 %of cross sectional area2 ft. MGO - General Observation - 80% MISSING TILES START 10:00 TO 2:002 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR2 ft. SAM - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES10.7 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR15 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR15 ft. MGO - General Observation - 33" RCP-CTL20.3 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR40.2 ft. MGO - General Observation - 100% MISSTILES42.9 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO66.2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO91.4 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES97.3 ft. MGO - General Observation - 1 ROW TILES201.5 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR- CORROED & MISSING214.9 ft. MGO - General Observation - 1 ROW TILES221.7 ft. MGO - General Observation - 2 ROWS MISSING TILES248.4 ft. MGO - General Observation - 3 ROWS TILES275.1 ft. MGO - General Observation - 100% MISSING TILES FINISH275.1 ft. SAM - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG275.1 ft. MGO - General Observation - MH CONN 9:00 ACTIVE275.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - LONG & CIRCUM REBAR275.6 ft. AMH - Downstream Manhole, Survey Ends - 5:25AM

Observation photos (13)

  • General Observation - 80% MISSING TILES START 10:00 TO 2:00

    2 ft. - General Observation - 80% MISSING TILES START 10:00 TO 2:00

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

    2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

  • Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES

    2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

    10.7 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

    15 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

  • General Observation - 33" RCP-CTL

    15 ft. - General Observation - 33" RCP-CTL

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

    20.3 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

  • General Observation - 100% MISSTILES

    40.2 ft. - General Observation - 100% MISSTILES

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO

    42.9 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO

    66.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES

    91.4 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES

  • General Observation - 1 ROW TILES

    97.3 ft. - General Observation - 1 ROW TILES

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR- CORROED & MISSING

    201.5 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR- CORROED & MISSING

Observations (25)

DistanceCodeObservation
275.1MGO100% MISSING TILES FINISH
214.9MGO1 ROW TILES
66.2SRC
0MGOMH CONN 9:00 OPEN
15SRCLONG & CIRCUM REBAR
91.4SRC
2MGO80% MISSING TILES START 10:00 TO 2:00
248.4MGO3 ROWS TILES
40.2MGO100% MISSTILES
275.6AMH5:25AM
2SRCLONG & CIRCUM REBAR
20.3SRCLONG & CIRCUM REBAR
275.1SAMSEVERE AGG
10.7SRCLONG & CIRCUM REBAR
275.1MGOMH CONN 9:00 ACTIVE
0AMH4:50AM
201.5SRCCIRCUM REBAR- CORROED & MISSING
275.1SRCLONG & CIRCUM REBAR
2SAMSEVERE AGG AREAS OF MISSING TILES
0MWL
0MWM
42.9SRC
221.7MGO2 ROWS MISSING TILES
97.3MGO1 ROW TILES
15MGO33" RCP-CTL

Properties (6)

custom_field_three
LONG & CIRCUM REBAR CORRODED & MISSING
custom_field_two
1
customer
LACSD
datetime
2017-12-21T02:21:17-08:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false