Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 22, 2016, 08:43 AM
  • G 0215_G 0214_20160722_014412.mp4

Date
07/22/2016
W/O
582914
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01180
PipeID
P01119
Time
1:43 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3619
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
SOUTH GATE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
WO_582914_TV01100_JULY2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
G 0215
Downstream MH
G 0214
Dir. of Survey
Downstream
Length Surveyed
179.3 ft.
Total Length
179.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2F00
O&M Rating
72
Overall Index
2
Overall Quick
Overall Rating
72
Pipe schematic from manhole G 0215 to G 0214
MH: G 0215MH: G 0214downstream0 ft. AMH - Upstream Manhole, Survey Begins - G 02150 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start56.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"105.3 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6"179.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish179.3 ft. AMH - Downstream Manhole, Survey Ends - G 0214179.3 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOC179.3 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    105.3 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • General Observation - COCKROACHES IN MANHOLE

    179.3 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (10)

DistanceCodeObservation
56.4TFA
0AMHG 0215
0MWM
105.3TFD
179.3DAGS
179.3AMHG 0214
0MWL
179.3MGOACTIVE CONNECTION AT MH 9 O'CLOC
179.3MGOCOCKROACHES IN MANHOLE
2DAGS

Properties (7)

additional_info
SC305798
custom_field_two
4
customer
LACSD
datetime
2016-07-22T01:43:46-07:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIPP