Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 20, 2016, 09:57 AM
  • G 0186_G 0185_20072016_025815.mp4

Date
07/20/2016
W/O
582914
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01180
PipeID
P01090
Time
2:57 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3617
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
LYNWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
WO_582914_TV01100_JULY2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
G 0186
Downstream MH
G 0185
Dir. of Survey
Downstream
Length Surveyed
21.4 ft.
Total Length
21.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2400
O&M Rating
8
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole G 0186 to G 0185
MH: G 0186MH: G 0185downstream0 ft. AMH - Upstream Manhole, Survey Begins - G 0186, ABANDONED THROUGH LINING.0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start20.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish21.4 ft. AMH - Downstream Manhole, Survey Ends - G 018521.4 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0AMHG 0186, ABANDONED THROUGH LINING.
0MWM
2DAGS
21.4AMHG 0185
21.4MGOACTIVE CONNECTION AT MH 3 O'CLOCK
0MWL
20.2DAGS

Properties (7)

additional_info
SC305796
custom_field_two
4
customer
LACSD
datetime
2016-07-20T02:57:37-07:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIPP