21 1007_21 1006_20160426_043836.mp4
137 ft. - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 4", 2"
187.4 ft. - Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES
212.4 ft. - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES
236.3 ft. - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 4"
238.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
315.5 ft. - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 4"
353.9 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 212.4 | FC | — |
| 137 | TBI | — |
| 134.2 | TF | — |
| 315.5 | TB | — |
| 371.2 | MGO | CONNECTION AT THE MH 9 OC'LOCK |
| 212.4 | TFC | — |
| 368.9 | TFC | — |
| 324.7 | TFC | — |
| 65.2 | TFC | — |
| 0 | VC | — |
| 371.2 | AMH | 21 1006 |
| 0 | MWL | — |
| 238.3 | CM | — |
| 0 | AMH | 21 1007 |
| 371.2 | VC | — |
| 353.9 | CM | — |
| 236.3 | TB | — |
| 165.1 | TFC | — |
| 0 | MWM | — |
| 0 | MGO | CONNECTION AT THE MH 3 OC'LOCK |
| 264.4 | TFC | — |
| 16.2 | TFC | — |
| 186.9 | TB | — |
| 187.4 | CM | — |
| 86.4 | TB | — |