Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 28, 2017, 01:49 PM
  • 08 0540_08 0539_10282017_072248.mp4

Date
10/28/2017
W/O
0635424
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00021
PipeID
P00602
Time
6:49 AM
Certificate
U115-0622630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0664
Sewer Name
08 VICTORIA STREET TRUNK
City
RANCHO DOMINGUEZ
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Capital Improvement Program Assesment
Project
10282017VMR_VICTORIA_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
08 0540
Downstream MH
08 0539
Dir. of Survey
Downstream
Length Surveyed
280.2 ft.
Total Length
280.2 ft.
Structural Index
1
Structural Quick
1A00
Structural Rating
12
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
1
Overall Quick
Overall Rating
12
Pipe schematic from manhole 08 0540 to 08 0539
MH: 08 0540MH: 08 0539downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 07:21 AM22.5 ft. CC - Crack Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES30.6 ft. CC - Crack Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES58.9 ft. CC - Crack Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES83.2 ft. CC - Crack Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES168.5 ft. CC - Crack Circumferential, from 09 to 01 o'clock, within 8 inches of joint: YES176.6 ft. CC - Crack Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES188.9 ft. CC - Crack Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES201 ft. CC - Crack Circumferential, from 09 to 01 o'clock, within 8 inches of joint: YES213.2 ft. CC - Crack Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES221.2 ft. CC - Crack Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES229.3 ft. CC - Crack Circumferential, from 11 to 02 o'clock, within 8 inches of joint: YES237.2 ft. CC - Crack Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES280.2 ft. AMH - Downstream Manhole, Survey Ends - 07:44 AM

Observation photos (1)

  • Crack Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES

    22.5 ft. - Crack Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
213.2CC
237.2CC
0MWM
280.2AMH07:44 AM
0MWL
168.5CC
176.6CC
188.9CC
83.2CC
0AMH07:21 AM
30.6CC
221.2CC
58.9CC
229.3CC
22.5CC
201CC

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2017-10-28T06:49:22-07:00
documentation
REVELES, MANANES, OLIVER III
is_lateral_inspection
false