Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 19, 2017, 10:36 AM
  • 02 0182_02 0181_7192017_040546.mp4

Date
07/19/2017
W/O
0647471
Weather
Dry
Operator/Surveyor
Reveles
Sewer ID
Z00251
PipeID
P04538
Time
3:36 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0595
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
25
Purpose
Capital Improvement Program Assesment
Project
20170714VMR_DOWNEY_BELLFOWER_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
02 0182
Downstream MH
02 0181
Dir. of Survey
Downstream
Length Surveyed
376.5 ft.
Total Length
376.5 ft.
Structural Index
2
Structural Quick
2311
Structural Rating
7
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
9
Pipe schematic from manhole 02 0182 to 02 0181
MH: 02 0182MH: 02 0181downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 0412 am44.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"47.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"99.6 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4"102.6 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"143 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4"146 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"155.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 03 o'clock, , within 8 inches of joint: YES181.5 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES195.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4"197.8 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"233.4 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES233.4 ft. CC - Crack Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES244.6 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4"247.1 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 4"247.4 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"296.8 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4"300 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"329.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES351.7 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4"355 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4"373 ft. MGO - General Observation - Mag Coat from 9:00 to 3:00 throughout the reach376.5 ft. AMH - Downstream Manhole, Survey Ends - 5:08 am

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, at 03 o'clock,  , within 8 inches of joint: YES

    155.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, at 03 o'clock, , within 8 inches of joint: YES

  • Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 4"

    247.1 ft. - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 4"

Observations (25)

DistanceCodeObservation
143TFC
47.5TFC
44.7TFC
247.1TB
99.6TFC
195.3TFC
155.2DAGS
197.8TFC
233.4CL
0MWM
0MWL
0AMH0412 am
355TF
300TFC
351.7TFC
247.4TFC
146TFC
329.3CL
102.6TFC
181.5CL
296.8TFC
244.6TFC
233.4CC
376.5AMH5:08 am
373MGOMag Coat from 9:00 to 3:00 throughout the reach

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2017-07-19T03:36:17-07:00
documentation
REVELES, MANANES, OLIVER
is_lateral_inspection