Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 18, 2017, 10:06 AM
  • 02 0210_02 0209_7182017_052917.mp4

Date
07/18/2017
W/O
0647471
Weather
Dry
Operator/Surveyor
Reveles
Sewer ID
Z00251
PipeID
P04543
Time
3:06 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0594
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
25
Purpose
Capital Improvement Program Assesment
Project
20170714VMR_DOWNEY_BELLFOWER_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0210
Downstream MH
02 0209
Dir. of Survey
Downstream
Length Surveyed
377.8 ft.
Total Length
377.8 ft.
Structural Index
2
Structural Quick
3228
Structural Rating
31
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
31
Pipe schematic from manhole 02 0210 to 02 0209
MH: 02 0210MH: 02 0209downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Downstream Manhole, Survey Begins - 05:19 am37.9 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4" - Open42.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES49.2 ft. CC - Crack Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES71.1 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES74 ft. CC - Crack Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES100.9 ft. CC - Crack Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES107.1 ft. CC - Crack Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES240.4 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4" - Open254.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES257.9 ft. CC - Crack Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES262.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Capped266.9 ft. CC - Crack Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES301 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES313.6 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES319.7 ft. CM - Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES321.2 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 4" - Open326 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES329 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES332.5 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES341.6 ft. CC - Crack Circumferential, from 09 to 02 o'clock, within 8 inches of joint: YES346.3 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4" - Capped350.9 ft. CC - Crack Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES357.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES366.6 ft. CC - Crack Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES368.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4" - Capped377.7 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 8"377.8 ft. AMH - Downstream Manhole, Survey Ends - 06:05 am

Observation photos (1)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    254.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (30)

DistanceCodeObservation
240.4TFOpen
341.6CC
326CL
262.6TFCCapped
37.9TFOpen
319.7CM
368.1TFCCapped
329CL
49.2CC
0MWL
321.2TFOpen
313.6CL
107.1CC
377.8AMH06:05 am
0MWM
357.8CL
100.9CC
257.9CC
71.1CL
377.7TFA
266.9CC
42.6CL
332.5CL
254.6CM
366.6CC
350.9CC
74CC
0AMH05:19 am
301CL
346.3TFCCapped

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2017-07-18T03:06:10-07:00
documentation
REVELES, MANANES, OLIVER
is_lateral_inspection
false